Lightning, Surge, and ESD Testing
 
Elite provides a wide variety of electrical transient testing services including industry standard waveforms to customized pulses. Our electrical engineers are capable of producing the methods and equipment to provide nearly any wave shape.

We utilize state-of-the-art arbitrary waveform generators along with high power amplifiers and dedicated burst generators. We also custom build R-C circuits to produce specialized pulses or high voltage long duration electrical surges.
 
Maximum High Voltage/Current Capabilities
  • Open circuit (Voltage) transients with maximum voltage of 50KV
  • Short circuit (Current) transients with maximum current of 20,000Amps
Lightning Surge/Burst Industry Standards

Commercial Aerospace
RTCA-DO-160, Section 22 Single and Multi-Stroke Capabilities
  • W/F 1; Cable or pin injection, 6.4us/70us, peak 3200A
  • W/F 2; Cable or pin injection, 100ns/6.4us, peak 1600V
  • W/F 3; Cable or pin injection, 1 – 50MHz, peak 3200V / 640A
  • W/F 4; Case-ground injection, 6.4us/70us, peak 1600V
  • W/F 5; Case-ground, injection, 40us/120us or 50us/500us, peak 2 kA
Multi-Burst W/F 3; Cable Injection, 1 & 10MHz, peak 60OV/120A

Military
  • CS115; Cable injected at 30ns rise time, 5 Amps
  • CS116; Cable injected at 10kHz – 100MHz damped sinusoids, 10Amps
  • CS10; Pins& Terminals / Navy
  • CS13; Single Wire Coupled Pulse / Air Force
  • CS11; Cable Injected / Navy
  • CS12; Common Mode Cable Injected / Air Force
Automotive and Truck Transients
Multiple Schaffner vehicle transient generators at Elite
  • SAEJ1113-11 Pulses 1, 2a, 2b, 3a, 3b, 4, 5 (Load Dump)
  • SAE J1455 Load Dump/ Mutual Coupling/ Inductive Switching
  • 12V and 24V systems
  • ISO 7637 Pulses 1, 2, 3a/3b, 4, 5
Nissan NDS 28400 Transients Toyota Field Decay, Load Dump

CE Mark/International Transients
  • EN 61000-4-4 Electrical Fast Transients
  • EN 61000-4-5 Surge 1.2 X 50 / 8 X 20 us
  • EN 61000-4-12 Damped Oscillatory 1 MHz
Telecommunications Lightning and Transients
  • Type A Telecom Surge
  • 10us/ 560us, 800V OC, 100A SC
  • 10us/ 160us, 1500V OC, 200A SC
  • Type B Telecom Surge
  • 9us/ 720us, 1000V OC, 25A SC
  • 10us/ 1000us, 1000V OC, 100A SC
  • Power Line Surge
  • 2us/10us, 5000V OC, 500A
Power Line Lightning Protection
  • IEEE ANSI C63.41—100kHz Ring wave 6kV, 0.2kA
  • ANSI C37.90.1—1.2us/50us, 8us/20us Combination Wave 6kV, 3kA
ESD Testing
61000-4-2, SAE J1113
  • Testing at levels from 100V to 30KV
  • Any combination of the following standard RC settings can be easily configured
    Resistance: (ohms)Capacitance: (picofarads)