Our Facility
Chamber R11M
- Primary Use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 20ft x 15ft x 10ft
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane: 16ft x 5.5ft x 0.031in. - Chamber Filtering:
- 3-50 Amp DC Filters
- Ground Plane Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 50 Amp
15VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request
Chamber R11P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer Bronze Screen, 1 layer 3oz Copper - Ground Plane:
- 12ft x 2.5ft x 0.031in.
- Chamber Filtering:
- 3 each 30 Amp DC filters
- Ground Plane Power Availability:
- 480VAC 60Hz 3Phase 60 Amp
240VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R12M
- Primary use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 15ft x 10ft,
2 layers of 32oz copper, 2 layers of Silicon Steel - Ground Plane:
- 16ft x 5.5ft x 0.031in.
- Chamber Filtering:
- 2 – DC 50 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 200 Amp
120VDC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R12P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer 32oz copper, 1 layer Steel - Ground Plane:
- 12ft x 2.5ft x 0.031in.
- Chamber Filtering
- 2 – DC 20 Amp filters
- Ground Plane Power Availability:
- 230VAC 60Hz 3Phase 30 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R16U
- Primary use:
- CISPR 25, Mil-Standard Aerospace, CE Mark Testing Room
- Description:
- Shielded Absorber Lined Ferrite Tile Lines Chamber;
23ft. x 24ft x 14ft, outside
19ft. x 20ft x 12ft, usable inside
2 layers Galvanized Steel - Ground Plane:
- 20ft x 7ft x 0.031in.
- Chamber Filtering:
- 4 – DC 60 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
120VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R23P
- Primary use:
- MIL-STD MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
15ft. x 12ft. x 10ft.
1 Layer 3oz Copper - Ground Plane:
- 8ft. x 2.5ft. x 1.5in.
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R19M
- Primary use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 15ft. x 20ft x 9ft,
2 layers of 32oz copper, 2 layers of Silicon Steel - Ground Plane:
- 16ft x 4ft x 0.031in.
- Chamber Filtering:
- 4 - 60 Amp DC filters
4 - 30 Amp DC filters - Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 60 Amp
120VAC 60Hz 1Phase 30 Amp
120VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R19P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 15ft. x 13ft x 9ft,
2 Layers 32oz. Copper, 2 Layers Steel - Ground Plane:
- 8ft x 4ft x 0.031in.
- Chamber Filtering:
- 2 - 20 Amp DC filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
240VAC 60Hz 3Phase 20 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R14N
- Primary use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 26ft. x 10ft x 12ft,
2 layers of 32oz copper, 2 layers of Silicon Steel - Ground Plane:
- 16ft x 4ft x 0.031in.
- Chamber Filtering:
- 4 – DC 60 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 30 Amp
120VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R14P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 15ft. x 13ft x 9ft,
2 Layers 32oz. Copper, 2 Layers Steel - Ground Plane:
- 8ft x 4ft x 0.031in.
- Chamber Filtering:
- 2 - 20 Amp DC filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
240VAC 60Hz 3Phase 20 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R27U
- Primary use:
- CISPR 25, CE Mark Testing Room
- Description:
- Shielded Absorber Lined Ferrite Tile Lines Chamber;
18ft. x 18ft x 12ft
2 layers Galvanized Steel - Ground Plane:
- 10ft x 3ft x 0.031in.
- Chamber Filtering:
- 4 - 30 Amp DC filters
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 20A
230VAC 60Hz 3Phase 50A
Note: Other power arrangements are available upon request.
Chamber R27P
- Primary use:
- CISPR 25, CE Mark Monitor Room
- Description:
- Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 8ft x 2.5ft x 0.031in.
- Ground Plane 2:
- 6.25ft x 2.5ft x 0.031in.
- Chamber Filtering:
- 4 – 20A DC Filters
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R28A
- Primary use:
- UNIVERSAL TEST ENCLOSURE
- Description:
- Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 11ft 3in x 3ft x 0.031in.
- Ground Plane 2:
- 10ft x 4.83ft x 0.031in.
- Chamber Filtering:
- 2 - 30 Amp DC filters
- Ground Plane Power Availability:
- External DC 30A
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R22A
- Primary use:
- AUTOMOTIVE TEST ENCLOSURE
- Description:
- 105ft. x 35ft x 18ft
1 Layer 3oz. Copper - Chamber Filtering:
- 1 – DC 30 Amp filter
- Ground Plane Power Availability:
- 230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 100 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R22P
- Primary use:
- AUTOMOTIVE MONITOR ENCLOSURE
- Description:
- 35ft. x 17ft x 10ft
1 Layer 3oz. Copper - Chamber Filtering:
- 1 – DC 30 Amp filter
- Ground Plane Power Availability:
- 208VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R21F
Primary use: FCC/CE TEST ENCLOSURE
Description: Shielded Absorber Lined Ferrite Tile Lines Chamber;
32ft. x 20ft x 18ft
2 layers Galvanized Steel
Chamber Filtering: 1 - DC 100 Amp filter
1 - AC 3 Phase 30 Amp Filter
1 - AC 3 Phase 60 Amp Filter
Ground Plane
Power Availability: External AC 3Phase 30 Amp
External DC 60 Amp
Note: Other power arrangements are available upon request.
Chamber R21P
- Primary use:
- FCC/CE MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
12ft. x 16t x 10ft
2 layers Galvanized Steel - Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R26A
- Primary use:
- AUTOMOTIVE TEST ENCLOSURE
- Description:
- Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 8ft x 2.5ft x 0.031in.
- Ground Plane Power Availability:
- External AC/DC 30A
External DC 60A
Note: Other power arrangements are available upon request.
Chamber R25U
- Primary use:
- CISPR 25, CE Mark Testing Room
- Description:
- Ferrite tile all four walls and ceiling
RF Absorber parcel walls and ceiling
23.5ft. x 21.5ft x 18ft
1 Layer Galvanized Steel - Removable Ground Plane:
- 11ft x 4ft x 0.031in.
- Chamber Filtering:
- 4 – AC/DC 60 Amp power line filters
- Ground Plane Power Availability:
- External AC/DC 60A
Note: Other power arrangements are available upon request.
Chamber R25P
- Primary use:
- CISPR 25, CE Mark Monitor Room
- Description:
- Monitor Chamber;
10ft. x 10ft x 10ft
1 layer Galvanized Steel - Ground Plane:
- 8ft x 30in x 0.031in.
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R24S
- Primary use:
- REVERBERATION TEST ENCLOSURE
- Description:
- 16ft. x 12ft x 10ft
2 Layers Galvanized Steel
Wall Ground Plane - 9ft. x 2.5ft. x 0.031in.
Mode Tuned Ground Plane – 6ft. x 2.5ft. x 0.031in. - Distance from Waveguide to Front of Ground Plane:
- Wall Ground Plane - 0.76m or 2.5ft.
Mode Tuned Ground Plane – 2.13m or 7ft straight length
4.27m or 14ft. along ground plane to floor to wall and up wall. - Chamber Filtering:
- 3 - 30 Amp AC filters
2 – 30 Amp DC Filters - Test Room Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
Chamber R24P
- Primary use:
- MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
20ft. x 10ft. x 8ft.
2 Layers Galvanized Steel - Ground Plane:
- 8ft. x 2.5ft. x 0.031in.
- Distance from Waveguide to Front of Ground Plane:
-
.84m or 32.9in. - Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R23L
- Primary use:
- MIL-STD MONITOR/LOAD ENCLOSURE
- Description:
- Monitor/LOAD Chamber;
10ft x 9ft x 10ft
1 Layer 3oz Copper - Ground Plane:
- 6ft x 2.5ft x 0.031in
- Load room filtering:
- 4 – AC/DC 30 Amp filters
- Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
480VAC 60Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
Chamber R23M
- Primary use:
- MIL-STD TEST ENCLOSURE
- Description:
- Anechoic Absorber Lined
31ft. x 23ft. x 18ft
2 Layers 32oz. Copper
2 Layers Silicon Steel - Ground Plane:
- 31ft. x 6ft. x 0.031in.
- Chamber Filtering:
- 2 – 28VDC 60 Amp filters
- Ground Plane Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Monitor Room R16P
- Primary use:
- CISPR 25, Mil-Standard Aerospace, CE Mark Monitor Room
- Description:
- Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane:
- 20ft x 7ft x 0.031in.
- Chamber Filtering:
- 4 – DC 60 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
20VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Click on one of the test chambers or monitor rooms below for a more detailed explanation.