Our Facility
Chamber R11M
- Primary Use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 20ft x 15ft x 10ft
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane: 16ft x 5.5ft x 0.031in. - Chamber Filtering:
- 3-50 Amp DC Filters
- Ground Plane Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 50 Amp
15VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request
Chamber R11P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer Bronze Screen, 1 layer 3oz Copper - Ground Plane:
- 12ft x 2.5ft x 0.031in.
- Chamber Filtering:
- 3 each 30 Amp DC filters
- Ground Plane Power Availability:
- 480VAC 60Hz 3Phase 60 Amp
240VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R12M
- Primary use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 15ft x 10ft,
2 layers of 32oz copper, 2 layers of Silicon Steel - Ground Plane:
- 16ft x 5.5ft x 0.031in.
- Chamber Filtering:
- 2 – DC 50 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 200 Amp
120VDC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R12P
- Primary use:
- Mil-Standard Aerospace Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer 32oz copper, 1 layer Steel - Ground Plane:
- 12ft x 2.5ft x 0.031in.
- Chamber Filtering
- 2 – DC 20 Amp filters
- Ground Plane Power Availability:
- 230VAC 60Hz 3Phase 30 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R16U
- Primary use:
- CISPR 25, Mil-Standard Aerospace, CE Mark Testing Room
- Description:
- Shielded Absorber Lined Ferrite Tile Lines Chamber;
23ft. x 24ft x 14ft, outside
19ft. x 20ft x 12ft, usable inside
2 layers Galvanized Steel - Ground Plane:
- 20ft x 7ft x 0.031in.
- Chamber Filtering:
- 4 – DC 60 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
120VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R23P
- Primary use:
- MIL-STD MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
15ft. x 12ft. x 10ft.
1 Layer 3oz Copper - Ground Plane:
- 8ft. x 2.5ft. x 1.5in.
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R19M
- Primary use:
- Mil-Standard Aerospace Testing
- Description:
- Shielded Absorber Lined Chamber; 15ft. x 20ft x 9ft,
2 layers of 32oz copper, 2 layers of Silicon Steel - Ground Plane:
- 16ft x 4ft x 0.031in.
- Chamber Filtering:
- 4 - 60 Amp DC filters
4 - 30 Amp DC filters - Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 60 Amp
120VAC 60Hz 1Phase 30 Amp
120VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R19P
- Primary use:
- Mil-Standard and Commercial Aviation Testing Monitor Room
- Description:
- Shielded Absorber Lined Chamber; 15ft. x 13ft x 9ft,
2 Layers 32oz. Copper, 2 Layers Steel - Ground Plane:
- 8ft x 4ft x 0.031in.
- Chamber Filtering:
- 2 - 20 Amp DC filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 30 Amp
240VAC 60Hz 3Phase 20 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R14ML
- Primary use:
- Mil-Standard and Commercial Aviation Testing
- Description:
- 100MHz to 18 GHz Test Frequency Range
- Ground Plane:
- Mode Tuned Chamber; 21ft. x 19ft x 16ft,
2 Layer Galvanized Steel Construction
- Chamber Filtering:
- 16ft x 4ft x 0.031in.
- Ground Plane Power Availability:
- 3 - 30Amp AC Filters
- 4 -30 Amp DC Filters
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
- Contact the Elite sales department for a detailed description of the room details.
Chamber R14P
- Primary use:
- Mil-Standard and Commercial Aviation Testing Room
- Monitor Room/ Reverberation Test Enclosure
- Description:
- Shielded Chamber; 10ft. x 9ft x 8ft,
26 Gauge Galvanized Steel Laminate on each side of 0.75 high-density wood core. - Ground Plane:
- 7ft x 4ft x 0.031in.
- Chamber Filtering:
- 3 - 30 Amp AC filters
- 4 - 30 Amp DC filters
- Ground Plane Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.

Chamber R27U
- Primary use:
- CISPR 25, CE Mark Testing Room
- Description:
- Shielded Absorber Lined Ferrite Tile Lines Chamber;
18ft. x 18ft x 12ft
2 layers Galvanized Steel - Ground Plane:
- 10ft x 3ft x 0.031in.
- Chamber Filtering:
- 4 - 30 Amp DC filters
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 20A
230VAC 60Hz 3Phase 50A
Note: Other power arrangements are available upon request.
Chamber R27P
- Primary use:
- CISPR 25, CE Mark Monitor Room
- Description:
- Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 8ft x 2.5ft x 0.031in.
- Ground Plane 2:
- 6.25ft x 2.5ft x 0.031in.
- Chamber Filtering:
- 4 – 20A DC Filters
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R28A
- Primary use:
- UNIVERSAL TEST ENCLOSURE
- Description:
- Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 11ft 3in x 3ft x 0.031in.
- Ground Plane 2:
- 10ft x 4.83ft x 0.031in.
- Chamber Filtering:
- 2 - 30 Amp DC filters
- Ground Plane Power Availability:
- External DC 30A
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R22A
- Primary use:
- AUTOMOTIVE TEST ENCLOSURE
- Description:
- 105ft. x 35ft x 18ft
1 Layer 3oz. Copper - Chamber Filtering:
- 1 – DC 30 Amp filter
- Ground Plane Power Availability:
- 230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 100 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R22P
- Primary use:
- AUTOMOTIVE MONITOR ENCLOSURE
- Description:
- 35ft. x 17ft x 10ft
1 Layer 3oz. Copper - Chamber Filtering:
- 1 – DC 30 Amp filter
- Ground Plane Power Availability:
- 208VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R21F
Primary use: FCC/CE TEST ENCLOSURE
Description: Shielded Absorber Lined Ferrite Tile Lines Chamber;
32ft. x 20ft x 18ft
2 layers Galvanized Steel
Chamber Filtering: 1 - DC 100 Amp filter
1 - AC 3 Phase 30 Amp Filter
1 - AC 3 Phase 60 Amp Filter
Ground Plane
Power Availability: External AC 3Phase 30 Amp
External DC 60 Amp
Note: Other power arrangements are available upon request.
Chamber R21P
- Primary use:
- FCC/CE MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
12ft. x 16t x 10ft
2 layers Galvanized Steel - Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R26A
- Primary use:
- AUTOMOTIVE TEST ENCLOSURE
- Description:
- Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane 1:
- 8ft x 2.5ft x 0.031in.
- Ground Plane Power Availability:
- External AC/DC 30A
External DC 60A
Note: Other power arrangements are available upon request.
Chamber R25U
- Primary use:
- CISPR 25, CE Mark Testing Room
- Description:
- Ferrite tile all four walls and ceiling
RF Absorber parcel walls and ceiling
23.5ft. x 21.5ft x 18ft
1 Layer Galvanized Steel - Removable Ground Plane:
- 11ft x 4ft x 0.031in.
- Chamber Filtering:
- 4 – AC/DC 60 Amp power line filters
- Ground Plane Power Availability:
- External AC/DC 60A
Note: Other power arrangements are available upon request.
Chamber R25P
- Primary use:
- CISPR 25, CE Mark Monitor Room
- Description:
- Monitor Chamber;
10ft. x 10ft x 10ft
1 layer Galvanized Steel - Ground Plane:
- 8ft x 30in x 0.031in.
- Ground Plane Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R24S
- Primary use:
- REVERBERATION TEST ENCLOSURE
- Description:
- 16ft. x 12ft x 10ft
2 Layers Galvanized Steel
Wall Ground Plane - 9ft. x 2.5ft. x 0.031in.
Mode Tuned Ground Plane – 6ft. x 2.5ft. x 0.031in. - Distance from Waveguide to Front of Ground Plane:
- Wall Ground Plane - 0.76m or 2.5ft.
Mode Tuned Ground Plane – 2.13m or 7ft straight length
4.27m or 14ft. along ground plane to floor to wall and up wall. - Chamber Filtering:
- 3 - 30 Amp AC filters
2 – 30 Amp DC Filters - Test Room Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
Chamber R24P
- Primary use:
- MONITOR ENCLOSURE
- Description:
- Monitor Chamber;
20ft. x 10ft. x 8ft.
2 Layers Galvanized Steel - Ground Plane:
- 8ft. x 2.5ft. x 0.031in.
- Distance from Waveguide to Front of Ground Plane:
-
.84m or 32.9in. - Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R23L
- Primary use:
- MIL-STD MONITOR/LOAD ENCLOSURE
- Description:
- Monitor/LOAD Chamber;
10ft x 9ft x 10ft
1 Layer 3oz Copper - Ground Plane:
- 6ft x 2.5ft x 0.031in
- Load room filtering:
- 4 – AC/DC 30 Amp filters
- Power Availability:
- 115VAC 60Hz 1Phase 15 Amp outlets
480VAC 60Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
Chamber R23M
- Primary use:
- MIL-STD TEST ENCLOSURE
- Description:
- Anechoic Absorber Lined
31ft. x 23ft. x 18ft
2 Layers 32oz. Copper
2 Layers Silicon Steel - Ground Plane:
- 31ft. x 6ft. x 0.031in.
- Chamber Filtering:
- 2 – 28VDC 60 Amp filters
- Ground Plane Power Availability:
- 115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Monitor Room R16P
- Primary use:
- CISPR 25, Mil-Standard Aerospace, CE Mark Monitor Room
- Description:
- Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel - Ground Plane:
- 20ft x 7ft x 0.031in.
- Chamber Filtering:
- 4 – DC 60 Amp filters
- Ground Plane Power Availability:
- 208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
20VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Tira 12,000 (V1)
- Primary Use:
- Vibration/Shock Testing
- Vibration Capabilities:
- Frequency: 5-3,000 Hz
Displacement: 2" peak to peak
Force Pound Capability: 12,000 - Mechanical Shock:
- Typical shock capability for a 100 lb fixture
*Contact Elite for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Slip Plate Size:
- 30" X 30"
- Armature Diameter:
- 15"
- Elite ID:
- EVE0
- Special Features:
- This vibration table can be fitted with a thermal chamber for combined environment temperature-vibration testing.
- Mounting Hole Patterns:
- View here


C60 6,000 (V2)
- Primary Use:
- Vibration/Shock Testing
- Vibration Capabilities
- Frequency: 5-3,000 Hz
Displacement: 1" peak to peak
Force Pound Capability: 6,000 - Mechanical Shock:
- Typical Shock capability for a 100 lb fixture and test item
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Slip Plate Size:
- 24" X 24"
- Armature Diameter:
- 15"
- Elite ID:
- EVA0
- Special Features:
- This vibration table can be fitted with a thermal chamber for combined environment temperature-vibration testing.
- Mounting Hole Pattern:
- View here

UD 19,000 (V3)
- Primary Use:
- Vibration/Shock Testing
- Vibration Capabilities
- Frequency: 5-2,500 Hz
Displacement: 1" peak to peak
Force Pound Capability: 19,000 - Mechanical Shock:
- Typical Shock capability for a 100 lb fixture and test item
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Slip Plate Size:
- 48" X 48"
- Armature Diameter:
- 15"
- Elite ID:
- EVG1
- Special Features:
- This vibration table can be fitted with a thermal chamber for combined environment temperature-vibration testing.
- Mounting Hole Pattern:
- View here

UD 17,000 (V5)
- Primary Use:
- Vibration/Shock Testing
- Vibration Capabilities
- Frequency: 5-2,500 Hz
Displacement: 1.5" peak to peak
Force Pound Capability: 17,000 - Mechanical Shock:
- Typical Shock capability for a 100 lb fixture and test item
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Slip Plate Size:
- 36" X 36"
- Armature Diameter:
- 15"
- Elite ID:
- EVG0
- Special Features:
- This vibration table can be fitted with a thermal chamber for combined environment temperature-vibration testing.
- Mounting Hole Pattern:
- View here
Ling 6,000 (V6)
- Primary Use:
- Vibration/Shock Testing
- Vibration Capabilities
- Frequency: 5-2,000 Hz
Displacement: 1" peak to peak
Force Pound Capability: 6,000 - Mechanical Shock:
- Typical Shock capability for a 100 lb fixture and test item
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Slip Plate Size:
- 30" X 30"
- Armature Diameter:
- 15"
- Elite ID:
- EVD0
- Special Features:
- Combined environment (vibration with thermal cycling) testing is not available on this Ling system.
- Mounting Hole Pattern:
AVCO Drop Shock Machine (S1)
- Primary Use:
- Shock Testing
- Shock Pulse Characteristics:
- *Assume 100 lb load and fixture
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Table Dimensions:
- 60 cm x 40 cm
- Elite ID:
- ESK0
- Special Features:
AVCO Pneumatic Shock Machine (S2)
- Primary Use:
- Shock Testing
- Shock Pulse Characteristics:
- *Assume 100 lb load and fixture
*Contact sales@elitetest.com for custom capabilities for your application*Time Duration ½ Sine Saw-tooth 6msec 11msec 18msec - Drop Shock Table Dimensions:
- 60 cm x 40 cm
- Elite ID:
- ESK0
- Special Features:
Elite Stainless Steel AGREE Chamber (P-T-C1)
- Primary Use:
- Thermal Humidity and Shock testing
- Chamber Size:
- 37" x 32" x 30"
- Temperature Range:
- -73C to 200C
- Temp. Change Rate:
- 15C/minute
- Cooling Type:
- LN2
- Humidity Range:
- 20% to 95% RH
- Elite ID:
- EAB0
Thermotron AGREE Chamber (P-T-C25)
- Primary Use:
- Thermal and Shock testing
- Chamber Size:
- 44"w x 34"h x 40"d
- Temperature Range:
- -77C to 177C
- Temp. Change Rate:
- 3C/minute
- Cooling Type:
- LN2
BlueM Thermal Cycling Chamber (T-C5)
- Primary Use:
- Thermal Cycling testing
- Chamber Size:
- 1' x 1' x 1'
- Temperature Range:
- +25C to 343C
- Temp. Change Rate:
- 30C/minute
- Cooling Type:
- LN2
- Special Features:
- High Temperature (+343C)
BlueM Thermal Cycling Chamber (T-C6)
- Primary Use:
- Thermal Cycling testing
- Chamber Size:
- 1' x 1' x 1'
- Temperature Range:
- +25C to 343C
- Temp. Change Rate:
- 30C/minute
- Cooling Type:
- LN2
- Special Features:
- High Temperature (+343C)
High Temperature Chamber (HT-21)
- Primary Use:
- High temperature testing
- Chamber Size:
- 38" x 20" x 26"
- Temperature Range:
- 23C to 185C
- Temp. Change Rate:
- 2C/min
- Special Features:
Russell AGREE Chamber (P-T-C2)
- Primary Use:
- Thermal Humidity and Shock testing
- Chamber Size:
- 54" x 54" x 54"
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 15C/minute
- Cooling Type:
- LN2
- Humidity Range:
- 20% to 95% RH
- Elite ID:
- EVGA
BlueM Thermal Cycling Chamber (T-C4)
- Primary Use:
- Thermal Cycling testing
- Chamber Size:
- 3' x 3' x 3'
- Temperature Range:
- -100C to 200C
- Temp. Change Rate:
- 15C/minute
- Cooling Type:
- LN2
- Special Features:
BlueM Thermal Shock Chamber (T-S7)
- Primary Use:
- Thermal Shock testing
- Chamber Size:
- 13W x 18H x 12D
- Temperature Range:
- -100C to +200C
- Temp. Change Rate:
- Transfer Time = 15 seconds.
- Cooling Type:
- LN2
BlueM Thermal Shock Chamber (T-S8)
- Primary Use:
- Thermal Shock testing
- Chamber Size:
- 13W x 18H x 12D
- Temperature Range:
- -100C to 200C
- Temp. Change Rate:
- Transfer Time = 15 seconds.
- Cooling Type:
- LN2
BlueM Thermal Shock Chamber (T-S9)
- Primary Use:
- Thermal Shock testing
- Chamber Size:
- 13W x 18H x 12D
- Temperature Range:
- -100C to 200C
- Temp. Change Rate:
- Transfer Time = 15 seconds.
- Cooling Type:
- LN2
Thermotron Temperature Altitude Humidity Chamber (T-A-H10 TT)
- Primary Use:
- Temperature, altitude and humidity testing
- Chamber Size:
- 4' x 4' x 4'
- Altitude Range:
- <100,000 ft
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 3C/min
- Humidity Range:
- 20% to 95% RH
- Cooling Type:
- Compressor
- Special Features:

Thermotron Thermal Cycling Humidity Chamber (T-C-H12 TT)
- Primary Use:
- Thermal Cycling testing
- Chamber Size:
- 4' x 4' x 4'
- Temperature Range:
- -55C to 150C
- Temp. Change Rate:
- 5C/min
- Cooling Type:
- Compressor
- Humidity Range:
- 20% to 95% RH
- Special Features:
Thermotron Thermal Shock Chamber (T-S13 TT)
- Primary Use:
- Thermal Shock testing
- Chamber Size:
- 24" x 24" x 24"
- Temperature Range:
- -74C to 177C
- Temp. Change Rate:
- Transfer Time = 15 seconds.
- Cooling Type:
- Compressor
- Special Features:
- Feed through on top of chamber. Recommended harness length = 20ft.
Altitude Vessel (A14 AltVes)
- Primary Use:
- Altitude testing
- Chamber Size:
- 20" x 28" x 20"
- Altitude Range:
- 65,000 ft
- Special Features:
- Configurable for rapid decompression testing.
Thermotron Temperature and Altitude Chamber (T-A15 TT)
- Primary Use:
- Thermal Altitude testing
- Chamber Size:
- 20" x 20" x 20"
- Temperature Range:
- 25C to 60C
- Temp. Change Rate:
- 2C/min
- Cooling Type:
- LN2
- Altitude Range:
- 65,000 ft
- Special Features:
- Configurable for rapid decompression testing.
Walk-In Thermal Cycling and Humidity Chamber (T-C-H16 WI)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 5' W x 8'D x 7.5'H
- Temperature Range:
- -50C to 85C
- Temp. Change Rate:
- 3C/min
- Cooling Type:
- Compressor
- Relative Humidity:
- 50% to 95% RH
- Special Features:
- Primary door panel is removable to accommodate large test items.
Thermotron Thermal Cycling and Humidity Chamber (T-C-H17 TT)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 27"D x 40" W x 34"H
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 5C/min
- Cooling Type:
- Compressor
- Relative Humidity:
- 5% to 98% RH
- Special Features:
Thermotron Thermal Cycling and Humidity Chamber (T-C-H18 TT)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 27"D x 40" W x 34"H
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 5C/min
- Cooling Type:
- Compressor
- Relative Humidity:
- 5% to 98% RH
- Special Features:
Thermotron Thermal Cycling and Humidity Chamber (T-C-H19 TT)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 3'D x 3' W x 3'H
- Temperature Range:
- -74C to 85C
- Temp. Change Rate:
- 2C/min
- Cooling Type:
- LN2/Compressor
- Relative Humidity:
- 20% to 95% RH
- Special Features:
BlueM Temperature and Humidity Chamber (T-H20 BlueM)
- Primary Use:
- Thermal and humidity testing
- Chamber Size:
- 3'W x 2' H x 1.5'D
- Temperature Range:
- 25C to 100C
- Temp. Change Rate:
- 2C/min
- Relative Humidity:
- 40% to 98% RH
- Special Features:
- Steam generated humidity.
Thermotron Thermal Cycling and Humidity Chamber (T-C-H22 TT)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 27"D x 40"W x 34"H
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 10C/min
- Cooling Type:
- Compressor
- Relative Humidity:
- 5% to 98% RH
- Special Features:
Thermotron Thermal Cycling and Humidity Chamber (T-C-H23 TT)
- Primary Use:
- Thermal cycling and humidity testing
- Chamber Size:
- 27"D x 40"W x 34"H
- Temperature Range:
- -73C to 177C
- Temp. Change Rate:
- 10C/min
- Cooling Type:
- Compressor
- Relative Humidity:
- 5% to 98% RH
- Special Features:
Small Salt Spray Chamber
- Primary Use:
- Corrosion and Salt spray testing
- Chamber Size:
- 42"W x 36"H x 30"D
- Temperature Range:
- 25C to 50C
- Salt Concentration:
- 5% salt solution or as specified
- Special Features:
Large Salt Spray Chamber
- Primary Use:
- Corrosion and Salt spray testing
- Chamber Size:
- 93"L x 48"W x 48"D
- Temperature Range:
- 25C to 50C
- Salt Concentration:
- 5% salt solution or as specified
- Special Features:
- click here to view video
Dust and Sand Chamber
- Primary Use:
- Mil-Std Dust and Sand testing
- Chamber Size:
- 4'L x 4'W x 4'D
- Temperature Range:
- 25C to 93C
- Temp. Change Rate:
- 2C/min
- Dust Types:
- Talc, silica flour, cement powder, Arizona road sand, and others.
- Special Features:
- Configurable for blowing dust or settling dust tests.
Explosive Atmosphere Chamber
- Primary Use:
- Volatile, flammable and explosive environment testing
- Chamber Size:
- 34"D x 24"W x 24"H
- Temperature Range:
- 25C to 85C
- Temp. Change Rate:
- 1-2C/min
- Altitude Range:
- <50,000 ft
- Special Features:
HALT/HASS Test Chamber (Thermotron Model AST-35)
- Primary Use:
- Combined environment and Highly Accelerated Life Testing
- Chamber Size:
- 3'L x 3'W x 3'D
- Temperature Range:
- -100C to 200C (-148F to 302F)
- Temp. Change Rate:
- 60C/min
- Cooling Type:
- LN2 (Liquid Nitrogen)
- Slip Plate Size:
- 28" x 28"
- Vibration System:
- 6-axis Repetitive shock
- Vibration Freq. Range:
- 2Hz-10Hz
- Maximum Weight:
- 480 lbs total weight for test item and fixture
- Special Features:
- *50 Grms, 8 additl. thermal couple boards/ports
*Three (3) 20" x 20" viewing windows
Custom-Built Acceleration Chamber (ACL1)
- Primary Use:
- Gravitational force testing
- Chamber Size:
- 14"W x 15"D x 18"H
- Slip Ring Terminals:
- Eighteen (18) terminal points
- Radius Arm Length:
- 36"
- Max. Sustained Gs:
- 75 Gs
MTS Force
- Primary Use:
- Chamber Size:
Magnification Station
- Primary Use:
- Magnification, Inspection and Photographic capabilities
Package Drop Test
- Primary Use:
- Simulate dropped products in transit
Solar Chamber
- Primary Use:
- Simulate the effects of solar exposure
MTS
Data for this chamber will be added shortly.
Chem Hood
Data for this chamber will be added shortly.
Water Exposure Testing
Data for this chamber will be added shortly.
Click on one of the test chambers or monitor rooms below for a more detailed explanation.