Elite Electronic Engineering Inc.
EMC and Environmental Stress Testing
Consulting, Certification, Program Management
1-800-Elite-11 Home| About Us| Site Map| Contact Us

Our Facility

Chamber R11M

Primary Use:
Mil-Standard Aerospace Testing
Description:
Shielded Absorber Lined Chamber; 20ft x 15ft x 10ft
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane: 16ft x 5.5ft x 0.031in.
Chamber Filtering:
3-50 Amp DC Filters
Ground Plane Power Availability:
115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 50 Amp
15VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request
Chamber R11M

Chamber R11P

Primary use:
Mil-Standard Aerospace Testing Monitor Room
Description:
Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer Bronze Screen, 1 layer 3oz Copper
Ground Plane:
12ft x 2.5ft x 0.031in.
Chamber Filtering:
3 each 30 Amp DC filters
Ground Plane Power Availability:
480VAC 60Hz 3Phase 60 Amp
240VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R11P

Chamber R12M

Primary use:
Mil-Standard Aerospace Testing
Description:
Shielded Absorber Lined Chamber; 20ft. x 15ft x 10ft,
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane:
16ft x 5.5ft x 0.031in.
Chamber Filtering:
2 – DC 50 Amp filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 200 Amp
120VDC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber R12M

Chamber R12P

Primary use:
Mil-Standard Aerospace Testing Monitor Room
Description:
Shielded Absorber Lined Chamber; 20ft. x 10ft x 8ft,
1 layer 32oz copper, 1 layer Steel
Ground Plane:
12ft x 2.5ft x 0.031in.
Chamber Filtering
2 – DC 20 Amp filters
Ground Plane Power Availability:
230VAC 60Hz 3Phase 30 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.

Chamber R16U

Primary use:
CISPR 25, Mil-Standard Aerospace, CE Mark Testing Room
Description:
Shielded Absorber Lined Ferrite Tile Lines Chamber;
23ft. x 24ft x 14ft, outside
19ft. x 20ft x 12ft, usable inside
2 layers Galvanized Steel
Ground Plane:
20ft x 7ft x 0.031in.
Chamber Filtering:
4 – DC 60 Amp filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
120VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR16U

Chamber R23P

Primary use:
MIL-STD MONITOR ENCLOSURE
Description:
Monitor Chamber;
15ft. x 12ft. x 10ft.
1 Layer 3oz Copper
Ground Plane:
8ft. x 2.5ft. x 1.5in.
Ground Plane Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.

Chamber R19M

Primary use:
Mil-Standard Aerospace Testing
Description:
Shielded Absorber Lined Chamber; 15ft. x 20ft x 9ft,
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane:
16ft x 4ft x 0.031in.
Chamber Filtering:
4 - 60 Amp DC filters
4 - 30 Amp DC filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 60 Amp
120VAC 60Hz 1Phase 30 Amp
120VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR19M

Chamber R19P

Primary use:
Mil-Standard Aerospace Testing Monitor Room
Description:
Shielded Absorber Lined Chamber; 15ft. x 13ft x 9ft,
2 Layers 32oz. Copper, 2 Layers Steel
Ground Plane:
8ft x 4ft x 0.031in.
Chamber Filtering:
2 - 20 Amp DC filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 30 Amp
240VAC 60Hz 3Phase 20 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR19P

Chamber R14N

Primary use:
Mil-Standard Aerospace Testing
Description:
Shielded Absorber Lined Chamber; 26ft. x 10ft x 12ft,
2 layers of 32oz copper, 2 layers of Silicon Steel
Ground Plane:
16ft x 4ft x 0.031in.
Chamber Filtering:
4 – DC 60 Amp filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 30 Amp
230VAC 60Hz 3Phase 30 Amp
120VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR14N

Chamber R14P

Primary use:
Mil-Standard Aerospace Testing Monitor Room
Description:
Shielded Absorber Lined Chamber; 15ft. x 13ft x 9ft,
2 Layers 32oz. Copper, 2 Layers Steel
Ground Plane:
8ft x 4ft x 0.031in.
Chamber Filtering:
2 - 20 Amp DC filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 30 Amp
240VAC 60Hz 3Phase 20 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR14P

Chamber R27U

Primary use:
CISPR 25, CE Mark Testing Room
Description:
Shielded Absorber Lined Ferrite Tile Lines Chamber;
18ft. x 18ft x 12ft
2 layers Galvanized Steel
Ground Plane:
10ft x 3ft x 0.031in.
Chamber Filtering:
4 - 30 Amp DC filters
Ground Plane Power Availability:
115VAC 60Hz 1Phase 20A
230VAC 60Hz 3Phase 50A
Note: Other power arrangements are available upon request.
ChamberR27U

Chamber R27P

Primary use:
CISPR 25, CE Mark Monitor Room
Description:
Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel
Ground Plane 1:
8ft x 2.5ft x 0.031in.
Ground Plane 2:
6.25ft x 2.5ft x 0.031in.
Chamber Filtering:
4 – 20A DC Filters
Ground Plane Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR27P

Chamber R28A

Primary use:
UNIVERSAL TEST ENCLOSURE
Description:
Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel
Ground Plane 1:
11ft 3in x 3ft x 0.031in.
Ground Plane 2:
10ft x 4.83ft x 0.031in.
Chamber Filtering:
2 - 30 Amp DC filters
Ground Plane Power Availability:
External DC 30A
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR28A

Chamber R22A

Primary use:
AUTOMOTIVE TEST ENCLOSURE
Description:
105ft. x 35ft x 18ft
1 Layer 3oz. Copper
Chamber Filtering:
1 – DC 30 Amp filter
Ground Plane Power Availability:
230VAC 60Hz 3Phase 30 Amp
480VAC 60Hz 3Phase 100 Amp
120VAC 60Hz 1Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR22A

Chamber R22P

Primary use:
AUTOMOTIVE MONITOR ENCLOSURE
Description:
35ft. x 17ft x 10ft
1 Layer 3oz. Copper
Chamber Filtering:
1 – DC 30 Amp filter
Ground Plane Power Availability:
208VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR22P

Chamber R21F

Primary use:        FCC/CE TEST ENCLOSURE
Description:    Shielded Absorber Lined Ferrite Tile Lines Chamber;
        32ft. x 20ft x 18ft
        2 layers Galvanized Steel
Chamber Filtering:    1 - DC 100 Amp filter
            1 - AC 3 Phase 30 Amp Filter
            1 - AC 3 Phase 60 Amp Filter    

Ground Plane
Power Availability:    External AC 3Phase 30 Amp
            External DC 60 Amp
            Note:     Other power arrangements are available upon request.


Chamber R21P

Primary use:
FCC/CE MONITOR ENCLOSURE
Description:
Monitor Chamber;
12ft. x 16t x 10ft
2 layers Galvanized Steel
Ground Plane Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Chamber21P

Chamber R26A

Primary use:
AUTOMOTIVE TEST ENCLOSURE
Description:
Monitor Chamber;
16ft. x 12ft x 10ft
2 layers Galvanized Steel
Ground Plane 1:
8ft x 2.5ft x 0.031in.
Ground Plane Power Availability:
External AC/DC 30A
External DC 60A
Note: Other power arrangements are available upon request.
ChamberR26A

Chamber R25U

Primary use:
CISPR 25, CE Mark Testing Room
Description:
Ferrite tile all four walls and ceiling
RF Absorber parcel walls and ceiling
23.5ft. x 21.5ft x 18ft
1 Layer Galvanized Steel
Removable Ground Plane:
11ft x 4ft x 0.031in.
Chamber Filtering:
4 – AC/DC 60 Amp power line filters
Ground Plane Power Availability:
External AC/DC 60A
Note: Other power arrangements are available upon request.
ChamberR25U

Chamber R25P

Primary use:
CISPR 25, CE Mark Monitor Room
Description:
Monitor Chamber;
10ft. x 10ft x 10ft
1 layer Galvanized Steel
Ground Plane:
8ft x 30in x 0.031in.
Ground Plane Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR25P

Chamber R24S

Primary use:
REVERBERATION TEST ENCLOSURE
Description:
16ft. x 12ft x 10ft
2 Layers Galvanized Steel
Wall Ground Plane - 9ft. x 2.5ft. x 0.031in.
Mode Tuned Ground Plane – 6ft. x 2.5ft. x 0.031in.
Distance from Waveguide to Front of Ground Plane:
Wall Ground Plane - 0.76m or 2.5ft.
Mode Tuned Ground Plane – 2.13m or 7ft straight length
4.27m or 14ft. along ground plane to floor to wall and up wall.
Chamber Filtering:
3 - 30 Amp AC filters
2 – 30 Amp DC Filters
Test Room Power Availability:
115VAC 400Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
ChamberR24S

Chamber R24P

Primary use:
MONITOR ENCLOSURE
Description:
Monitor Chamber;
20ft. x 10ft. x 8ft.
2 Layers Galvanized Steel
Ground Plane:
8ft. x 2.5ft. x 0.031in.
Distance from Waveguide to Front of Ground Plane:
 
.84m or 32.9in.
Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
ChamberR25P

Chamber R23L

Primary use:
MIL-STD MONITOR/LOAD ENCLOSURE
Description:
Monitor/LOAD Chamber;
10ft x 9ft x 10ft
1 Layer 3oz Copper
Ground Plane:
6ft x 2.5ft x 0.031in
Load room filtering:
4 – AC/DC 30 Amp filters
Power Availability:
115VAC 60Hz 1Phase 15 Amp outlets
480VAC 60Hz 3Phase 30 Amp
Note: Other power arrangements are available upon request.
ChamberR23L

Chamber R23M

Primary use:
MIL-STD TEST ENCLOSURE
Description:
Anechoic Absorber Lined
31ft. x 23ft. x 18ft
2 Layers 32oz. Copper
2 Layers Silicon Steel
Ground Plane:
31ft. x 6ft. x 0.031in.
Chamber Filtering:
2 – 28VDC 60 Amp filters
Ground Plane Power Availability:
115VAC 400Hz 3Phase 30 Amp
115VAC 60Hz 3Phase 30 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.

Monitor Room R16P

Primary use:
CISPR 25, Mil-Standard Aerospace, CE Mark Monitor Room
Description:
Monitor Chamber;
12ft. x 12ft x 10ft
2 layers Galvanized Steel
Ground Plane:
20ft x 7ft x 0.031in.
Chamber Filtering:
4 – DC 60 Amp filters
Ground Plane Power Availability:
208VAC 400Hz 3Phase 50Amp
480VAC 60Hz 3Phase 200 Amp
230VAC 60Hz 3Phase 50 Amp
20VAC 60Hz 1Phase 20 Amp
115VAC 60Hz 1Phase 15 Amp outlets
Note: Other power arrangements are available upon request.
Monitor Room R16P

Click on one of the test chambers or monitor rooms below for a more detailed explanation.

Note: *New Chambers and Environmental Lab will be clickable soon!*

Our Facility Mil/Aero Test Chamber R11M Monitor Room R11P Mil/Aero Test Chamber R12M Monitor Room R12P CISPR 25 Test Chamber R16U CISPR 25 Test Chamber R25U Mil/Aero Test Chamber R19M Monitor Room R19P Small Test Room R14N Monitor Room R14P CISPR 25 Test Chamber R27U Monitor Room R27P Monitor Room R28A Whole Vehicle Test Chamber R22A Monitor Room R22P 3 Meter Chamber R21F Monitor Room R21P Monitor Room R26A Monitor Room R25P Mode Stirred Chamber R24S Monitor Room R23L Mil/Aero Test Chamber R23M Monitor Room R23P Monitor Room R24P Monitor Room R16P

Internet Marketing & Web Design by Milwaukee Based Top Floor Technologies