Experience The Convenience Of Combined Thermal Testing
With a versatile suite of environmental test chambers, Elite can readily fit your products into the chamber environment that best suits your product application and test budget. Testing for relative humidity up to 95%, altitude up to 100,000 ft., and temperatures from -100 C to 350 C; Elite can test your products in extreme environments.
Climatic chamber capabilities include:
- Temperature ranging from -100 C (-150 F) to 350 C (660 F)
- Humidity ranging from 5% RH to 95% RH
- Altitude up to 100,000 ft
- Chamber sizes up to Walk-in (16ft x 11ft x 9 ft)
Climatic chamber types include:
- Temperature
- Temperature Cycle
- Temperature Shock / Thermal Shock
- Liquid to Liquid Thermal Shock
- Temperature/Humidity
- Temperature/Humidity/Altitude
- Temperature/Humidity/Vibration
- High Temperature Oven
- Rapid Decompression
- Salt and Water Spray
- Blowing Dust
- Settling Dust
- Flammability
- Solar Radiation
- Explosive Atmosphere
- HALT/HASS
Common Testing Standards:
- MIL-STD-810
- MIL-STD 202
- RTCA DO-160
- SAE J1455
- GM 3172
- Ford CETP 00.00-E-412
- Chrysler CS11982
- Nissan 28401NDS01
- Toyota
- CAT EC-1
- Navistar DR100159-05
- JDQ 201
- CNH ENS0310
- Harley EG-812-22611
- IEC 60068
- IEC 60529
- NEMA 250
- NEBS, ASTM, ANSI
- ISO 16750
Liquid to Liquid Thermal Shock Testing:
- Excellent heat exchange rate, providing immediate product temperature change
- Low temperature -65C to 0C
- High temperature +70C to +200C
- Basket size W150 X H150 X D200mm
- Nonconductive liquid does not coat the product or conduct electricity
- Reduce test time
- The expansion and contraction caused by the temperature variation generate stress from differences in the expansion rates of parts made of different materials
- The repeated action of stress causes accumulation of material fatigue, sometimes leading to rupturing at a lower strength than the static strength
- Repeated stress can cause coatings to peel and screens to loosen
Specialized Battery Testing:
- Climatic Chamber has built in safety measures for testing lithium ion batteries
- Size: 32 cubic feet
- Dimensions: 38"W x 38"H x 38"D
- Upper limit: (+85C)
- Lower Limit: (-70C)
- Weight limit: 500 lbs.
- Fire Suppression System
- Rated to Hazard Severity Level 5 (Fire or Flame)
- Digital High/Low Temperature Limit and Alarm
- Light Stack and Audible Alarm
- Heated Pressure Relief Port
- Electronic Safety Door Interlock (Prevents entry either during tests or after an event)
- Gas Monitor, interlocked to controller to shut down chamber
- External Chamber Light to eliminate potential for spark
- UN/DOT 38.3, MIL-PRF-32383, and other industry specs. Please contact an Elite Sales Engineer for any questions.